5700A - Mulit-Function Calibrators

Get a Quick Quote










Call for Price

5700A - Mulit-Function Calibrators


Since its introduction in 1988, the 5700A Multifunction Calibrator has earned a worldwide reputation for performance, dependability and quality, and as a result it is the calibrator of choice for electrical calibration throughout government and industry.

Today, the 5720A Multifunction Calibrator offers even more. In addition to the dependability, simplified calibration, ease-of-use and worldwide support that has made the 5700A number one, the 5720A offers uncertainty specifications that rival anything available today. Customers can get all the performance they need to calibrate their most demanding workload of multimeters up to 8 1/2 digits quickly, easily and reliably. This improvement in performance results from factory testing to even tighter tolerances, and from a variety of hardware and firmware improvements.

Specifications:
  • Ranges:
    • DC voltage to 1100 V
    • AC voltage to 1100 V, with output available from 10 Hz to 1 MHz
    • AC and DC current to 2.2 A, with output available from 10 Hz to 10 kHz
    • Resistance in values of 1x10n and 1.9x10n from 1 O to 100 MO, plus a short
  • Internal environmentally-controlled references allowing the calibrator to maintain full performance over a wide ambient temperature range
  • Automatic meter error calculation obtained through using a simple output adjust knob; the display shows linearity, offset, and scale errors
  • Keys that multiply and divide the output value by 10 to simplify work on meters with calibration points at decade multiples of a fraction of full-scale
  • Programmable entry limits used for restricting the levels that can be keyed into the calibrator, preventing access to levels that may be harmful to equipment or personnel
  • An auxiliary current binding post that allows you to calibrate meters with separate current inputs without moving cables
  • Real-time clock and calendar for date stamping reports
  • Offset and scaling modes that simplify linearity testing of multimeters
  • Variable phase reference signal output and phase-lock input
  • Interface for the Fluke 5725A Amplifier
  • IEEE-488 (GPIB) interface
  • Selectable normal remote mode or emulation of the Fluke 5100B and 5200A Series calibrators in functions and response to system controller software
  • RS-232C serial data interface for printing, displaying, or transferring internally-stored calibration constants, and for remote control of the calibrator
  • A traceable calibration procedure for all modes and ranges that requires only 10 V, 1 O, and 10 kO external standards, with only occasional independent verification
  • Fast, simple, automated calibration check providing added confidence between calibration recalls, and data that can be used to document and characterize the calibrator's performance between calibration recalls
  • 100, 110, 115, 120, 200, 220, 230, or 240 Vac ±10%; 47-63 Hz operation

Amabile Electronic Test is an independent distributor and is not affiliated with the manufacturers of the products it sells except where expressly noted