TagLine Here




Product Image Item Name- Price
8482H - Power Sensors

8482H - Power Sensors

The HP/Agilent 8482H thermocouple power sensor is designed for use with the EPM series, EPM-P series, 70100A, E1416A and the 435A/B, 436A, 437A/B, and 438A power meters. It operates from 100 kHz to 4.2 GHz at levels from -10 to +35 dBm with exceptional accuracy and stability. The 8482H has...


Call for Price





8483A - Power Sensors

8483A - Power Sensors

The 8483A diode power sensor measures average power over the frequency range 100 kHz to 2 GHz and power range -30 to +20 dBm (50 dB dynamic range). Key Features 75 ohm input impedance power sensor Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US...


Call for Price





8484A - Power Sensors

8484A - Power Sensors

The 8484A High Sensitivity Power Sensor measures power from 0.1nW to 10 uW over a frequency range of 10MHz to 18GHz. It is furnished with the 11708A 50MHz reference attenuator for precise calibration with 1 mW power meter reference oscillator. Noise and drift have been reduced to less than 5% of...


Call for Price





8485A - Power Sensors

8485A - Power Sensors

The 8485A power sensor is designed for use with the EPM series, EPM-P series, 70100A, E1416A, 435A/B, 436A, 437A, 438A series power meters. The 8485A provides extraordinary accuracy, stability, and lower SWR. Key Features Excellent SWR for reducing mismatch uncertainty Accurate calibration and...


Call for Price





8485D - Power Sensors

8485D - Power Sensors

The 8485D diode power sensor measures average power over the frequency range 50 MHz to 26.5 GHz and power range -70 to -20 dBm (50 dB dynamic range). The Agilent 11708A 30 dB attenuator is supplied with 8480 series power sensors with the "D" suffix, for calibration with the power meter 0 dBm, 50...


Call for Price





8487A - Power Sensors

8487A - Power Sensors

The 8487A thermocouple power sensor is designed for use with the EPM series, EPM-P series, 70100A, E1416A and the 435A/B, 436A, 437A/B, and 438A power meters. It operates from 50 MHz to 50 GHz at levels from -30 to +20 dBm with exceptional accuracy and stability. The 8487A has extremely low SWR and...


Call for Price





8487D - Power Sensors

8487D - Power Sensors

The 8487D diode power sensor measures average power over the frequency range 50 MHz to 50 GHz and power range -70 to -20 dBm (50 dB dynamic range). The Agilent 11708A 30 dB attenuator is supplied with 8480 series power sensors with the "D" suffix, for calibration with the power meter 0 dBm, 50 MHz...


Call for Price





E4413A - Power Sensors

E4413A - Power Sensors

The Agilent E4413A CW diode power sensor measures average power over the frequency range 50 MHz to 26.5 GHz and power range -70 to +20 dBm (90 dB dynamic range). Key Features Fast measurement speed, up to 400 readings per second with the E4416A Wide dynamic range (-70 dBm to +20 dBm) Frequency...


Call for Price





E9288B - Power Sensors

E9288B - Power Sensors

Agilent E9288B Power Sensor Cable (3.0m / 10 feet) The Agilent E9288B power sensor cable (blue) must be used with the E9320 family of peak and average power sensors, and is also compatible with all 8480 and E-series sensors.


Call for Price





E9288C - Power Sensors

E9288C - Power Sensors

Agilent E9288C Power Sensor Cable (10m / 31 feet) The E9288C power sensor cable (blue) must be used with the E9320 family of peak and average power sensors, and is also compatible with all 8480 and E-series sensors.


Call for Price






Amabile Electronic Test is an independent distributor and is not affiliated with the manufacturers of the products it sells except where expressly noted
otherwise. Any and all trademarks or logo rights associated with the manufacturer' names and products are owned by the respective manufacturers.
Copyright © 2024 Amabile Electronic Test. Powered by Zen Cart


Dawson Multimedia | Web Design Orlando..